ABC! WLED Controller V41/ESP32
Quantity | Unit price |
---|---|
To 1 |
€32.95*
|
To 2 |
€32.45*
|
From 3 |
€31.95*
|
Available, delivery time: 1-3 days
Description:
Scope of delivery:
- WLED controller in a housing (with or without digital microphone depending on the option selected), flashed and tested, so "ready-to-use"
- Usage information in printed form
Technical data:
- Supply voltage: 5 V +/- 0.1 V
- Ambient temperature operation: +5 °C … +35 °C
- WiFi standard: IEEE 802.11 b/g/n, 2.4 GHz
- Dimensions with housing 97x49x31 mm
- Maximum permanent current carrying capacity power path (+5V, GND): up to 13 A (depending on cable cross section and environment)
- Average power consumption in power on state (without load path): 0.50 W
- Average power consumption in power off (networked standby mode): 0.45 W
- Average power consumption in AP mode (configuration mode): 0.5 W
- Current consumption, peak (without load): 800 mA
- Efficiency at full load: 94%
- Power loss at full load: 4 W
- Ambient temperature storage/transport: -20 °C … 60 °C
- Screw terminals: Target torque: 0.4 Nm
- Screw terminals, cable cross section: 0.5 ... 2.5 mm2, rigid or flexible with wire end sleeve
- Screw terminals, stripping/sleeve length: 6-7 mm / 8 mm
- Protection rating with housing: IP20
- Antenna: integrated circuit board antenna 3.7 dBi
- Weight with case: 62 g
- The device is not intended for operation in an idle state.
- Maximum permanent current carrying capacity of the power path of the device (power supply connection to the LED strip connection, each for +5V and GND)*:
- Cable cross section / maximum permanent current carrying capacity (maximum output power)(*):
- 0.5 mm2 / 3 A (15 W)
- 0.75 mm2 / 6 A (30 W)
- 1 mm2 / 9 A (45 W)
- 1.5 mm2 - 2.5 mm2 / 13 A (65 W)
Mandatory information:
WEEE Reg. No.: DE34359026Hazard notes:
- This product is intended for use by persons with relevant electrical engineering knowledge and experience. This means that the person must be able to correctly dimension the light chain or lighting system to be set up (including, for example, selection of the power supply, the light chain, cable selection, any necessary safety elements) and to set it up using relevant electrical engineering standards. Incorrect or improper use can be dangerous. Please read these operating instructions completely before setting up your fairy lights or lighting system.
- This product may only be operated with safety extra-low voltage (SELF) (protection class III).
- This product is not a toy! It must be kept out of the reach of children and must not be used as a toy.
- When connecting to the device terminals, please note the permitted cables and cross sections.
- Please note the technical data, especially the maximum current carrying capacity of the power path. Overloading can lead to the destruction of this product and/or a fire and must be avoided by carefully designing the light chain or lighting system and, if necessary, integrating the safety elements both in normal operation and in the event of a fault.
- Install and connect this product only when there is no voltage! Make sure the polarity is correct!
- For safety and approval reasons (CE), unauthorized conversion and/or modification of the device is not permitted.
- We assume no liability for property damage or personal injury caused by improper use or failure to observe the hazard warnings. In these cases, the warranty claim also expires! We assume no liability for consequential damage.
- Keep the usage information digitally or printed so that you can always access it.
- This product is only suitable for use in apartment-like environments.
- Protect this product from electrostatic discharge to avoid damage.
- Any use other than that described in this usage information is not intended and leads to exclusion of warranty and liability.